RECI LASER 3.0 OPTICAL STANDARD • MODEL W2 (90W / 100W PEAK)

Reci W2 90W CO2 Laser Tube Engineering Specs & Current Limits

Authoritative engineering specifications for the Beijing Reci W2 (superseding S2/Z2) 90W nominal / 100W peak sealed glass CO2 laser tube. Complete physical dimensions (1200mm × 80mm), electrical benchmarks (19kV striking voltage, 18–24mA operating current envelope), TEM00 beam mode purity, and Reci DY13 high-voltage power supply matching guidelines.

🛒 Check Reci W2 90W Tube Price on Amazon → ⚡ View Verified Specifications
90W / 100W Rated / Peak Output
1200 mm Physical Tube Length
80 mm Outer Glass Diameter
18–24 mA Safe Working Current
VERIFIED ENGINEERING SPECIFICATIONS

Reci W2 90W Engineering & Optical Specifications

Operating limits, power requirements, and cooling standards:

ParameterFactory SpecificationOperational RuleRecommended Hardware
Output Optical Power90W Nominal continuous, 100W PeakNever overdrive past 100WView Reci W2 on Amazon →
Current Threshold (mA)Optimal: 18–22 mA | Max Safe: 24 mARunning >25mA causes catalyst breakdownView Analog mA Meter →
Striking / Working Voltage19 kV Trigger Voltage | 16 kV OperatingRequires dedicated 100W HV PSUView Reci DY13 Power Supply →
Chiller Cooling StandardDeionized water @ 18°C–22°C (64°F–72°F)Minimum flow rate: 4.0 LPMView CW-5200 Chiller →
BENCH SERVICE PROCEDURE

How to Wire and Current-Calibrate a Reci W2 90W Tube

Precise high-voltage wiring and milliampere meter calibration are vital for beam longevity:

STEP 1: ANODE HIGH-VOLTAGE CONNECTION

Solder & Insulate Positive Anode (+)

Strip high-voltage red lead from power supply. Wrap tightly around the tungsten pin at the rear anode. Solder cleanly and slide high-dielectric silicone tubing over the joint with silicone sealant.

STEP 2: CATHODE & mA METER LOOP

Wire Negative Cathode Through Meter

Connect the front negative cathode wire through an analog 0–30mA DC panel meter in series before terminating to the power supply return ground.

STEP 3: WATER CHILLER BUBBLE PURGE

Purge Air Bubbles from Cooling Jacket

Run CW-5200 chiller with distilled water. Ensure water enters the lower port and exits the upper port. Gently rotate the tube until zero trapped air bubbles cling to the internal spiral glass jacket.

STEP 4: CURRENT LIMIT TUNING

Calibrate Ruida Controller Max Power %

Set machine to pulse at 100% test power. Observe analog mA meter needle. Adjust the potentiometer on the Reci DY13 power supply until 100% software power corresponds to exactly 24.0 mA.

Check Analog mA Meter on Amazon →
FREQUENTLY ASKED QUESTIONS

Technical & Field Service FAQs

What happens if I run a Reci W2 above 24mA?

Running a Reci W2 tube above 24mA causes rapid sputtering of the internal platinum-catalyst cathode coating and thermal stress on the output coupler mirror. Exceeding 25mA can cut tube lifespan from 10,000 hours down to fewer than 500 hours.

What power supply is matched for Reci W2?

The Reci DY13 is factory-engineered specifically for Reci W2 and W4 tubes. It provides the exact 19kV striking voltage and fast current-limiting response needed to avoid resonant optical distortion.

Can I use tap water in my laser chiller?

NO! Tap water contains dissolved minerals and chlorine that conduct high-voltage electricity, cloud the internal glass water jacket, and cause algae growth that absorbs 10.6µm laser radiation. Always use pure distilled or deionized water.